Vertical-Mounted Masts

Specifications: Quick Erecting Antenna Masts (QEAM)

Model TM 6 TM 10 HDTM 10 TM 15
Nested Height 5ft 7in/1.7m 8ft/2.4m 8ft/2.4m 8ft/2.4m
Extended Height 19ft 8in/6m 32ft 10in/10m 32ft 10in/10m 50ft/15m
Guying 2 level/3 way 2 level/3 way 2 level/3 way 3 level/3 way
Number of Sections 5 5 6 8
Size/Shape Round w/ full length key Round w/ full length key Round w/ 2 full length keys Round w/ 2 full length keys
Material Aluminum 6061-T6 Aluminum 6061-T6 Aluminum 6061-T6 Aluminum 6061-T6
Weight (mast only) 30lb/14kg 42lb/19kg 110lb/50kg 135lb/61kg
Weight (accessory kit) 51lb/23kg 57lb/26kg 57lb/26kg 77lb/35kg
Payload capacity 15lb/7kg 15lb/7kg 75lb/34kg 75lb/34kg
Max. sail area 6sqft/0.6msq CD=1.5 6sqft/0.6msq CD=1.5 6sqft/0.6msq CD=1.5 6sqft/0.6msq CD=1.5
Ice load 0.5in/12mm 0.5in/12mm 0.5in/12mm 0.5in/12mm
Max. erection wind * 25mph/40kph 25mph/40kph 25mph/40kph 25mph/40kph
Operational wind 60mph/97kph 60mph/97kph 60mph/97kph 60mph/97kph
Survival wind 80mph/128kph 80mph/128kph 80mph/128kph 80mph/128kph
Operational stability ±15° ±15° ±15° ±15°
Deployment time 2 persons, 7.5 min 2 persons, 7.5 min 3 persons, 8 min 3 persons, 10 min
Deployment time 1 person, 15 min 1 person, 15 min 3 person, 8 min 3 person, 10 min
Drive system Screw drive with manual crank Screw drive with manual crank Screw drive with manual crank Screw drive with manual crank
Finish Mil-F-10472, AG Mil-F-10472, AG Mil-A-8625 Type III, CL 2 Black Mil-A-8625 Type III, CL 2 Black

* Note: Must be guyed for wind speeds over 25 mph/40 kph.

TM 10 (AB-1386/U) QEAM ™ MIL Spec Qualifications
High Temperature to +68°C: MIL-STD-810E, Method 501.3, Procedure II
Low Temperature to -51°C: MIL-STD-810E, Method 502.3, Procedure I and II
Altitude: MIL-STD-810E, Method 500.3, Procedure I and II
Humidity: MIL-STD-810E, Method 507.3, Procedure III
Fungus: MIL-STD-810E, Method 508.4
Salt Fog: MIL-STD-810E, Method 509.3
Sand and Dust: MIL-STD-810E, Method 510.2, Procedure I and II
Vibration, Loose Cargo Transport: MIL-STD-810E, Method 514.4, Para 1-3.2.3, Category 3, Procedure II
Shock, Transit Drop: MIL-STD-810E, Method 516.4, Procedure IV
Vibration, Ground Mobile: MIL-STD-810E, Method 514.4, Category 8, Table 1
Ice Load: MIL-STD-810E, Method 521.1
Rain: MIL-STD-810E, Method 506.3, Procedure I
Immersion: MIL-STD-810E, Method 512.3, Procedure I
Human Engineering: MIL-STD-1472

Specifications subject to change without notice.